Enterprise Access Hub

Enterprisegrade access hub with entry and exit control up to eight doors and battery backup support.

Volume Discounts
1 $1,564.99/ea
2-4 $1,558.62/ea
5-9 $1,552.24/ea
10-19 $1,539.49/ea
20+ $1,526.75/ea

Enterprise Access Hub

Fabricant Ubiquiti
Modèle EAH-8
UPC 810084693629
Catégorie Networking Wireless Dual Band — APs & Bridges
Poids 28.4 lbs
Dimensions (boîte) 8.7" × 23.1" × 20.1" (L×P×H)
ProductProductProductProduct
Overview
Dimensions 379 x 355 x 105 mm (15 x 14 x 4.1")
Supported Doors 8
Maximum User Count 10,000
Input Terminals (8) Door exit request (8) Door position (1) Emergency
Power Method Universal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32V
NDAA Compliant
UL 294 Level Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Weight Device: 9.1 kg (20 lb) Mount: 624 g (1.4 lb)
Enclosure Material SGCC steel housing with polycarbonate cover
Mount Material SGCC steel
Mounting Wall
Digital Input (8) Inputs for request-to-exit devices (8) Inputs for door position sensors (1) Emergency
Dry Output Relay (8) Lock terminals (12V or Dry) (4) AUX terminals for advanced setup (Chime/Siren/Door opener)
Powered Output Relay Lock: 12V DC, 1A/ Dry Aux: Dry only
Indoor and Outdoor Use Indoor only
Ambient Operating Temperature 0 to 40° C (32 to 104° F)
Ambient Operating Humidity 5 to 95% noncondensing
Networking Interface (10) 10/100/1000 Base-T
PoE Interface (8) PoE+ outputs, 50V DC, 30W per port (Max 60W aggregated)
Power Supply AC/DC, internal
Max. Power Consumption 240W
Max. PoE Wattage per Port 30W
LEDs W/B Learn More
Buttons (1) Factory reset
UA-Lock-Electric (400mA) 24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA) 24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA) 24 AWG length: 12 m (29 ft) 22 AWG length: 20 m (98 ft) 20 AWG length: 30 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A) 24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 Statement Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Grade Grade assignment: I
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level EAH-8, Ver 01
Management Application Access
Software Information The software version can be checked at https://unifi.ui.com
Specs
Dimensions 379 x 355 x 105 mm (15 x 14 x 4.1")
Supported Doors 8
Maximum User Count 10,000
Input Terminals (8) Door exit request (8) Door position (1) Emergency
Power Method Universal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32V
NDAA Compliant
UL 294 Level Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Weight Device: 9.1 kg (20 lb) Mount: 624 g (1.4 lb)
Enclosure Material SGCC steel housing with polycarbonate cover
Mount Material SGCC steel
Mounting Wall
Digital Input (8) Inputs for request-to-exit devices (8) Inputs for door position sensors (1) Emergency
Dry Output Relay (8) Lock terminals (12V or Dry) (4) AUX terminals for advanced setup (Chime/Siren/Door opener)
Powered Output Relay Lock: 12V DC, 1A/ Dry Aux: Dry only
Indoor and Outdoor Use Indoor only
Ambient Operating Temperature 0 to 40° C (32 to 104° F)
Ambient Operating Humidity 5 to 95% noncondensing
Networking Interface (10) 10/100/1000 Base-T
PoE Interface (8) PoE+ outputs, 50V DC, 30W per port (Max 60W aggregated)
Power Supply AC/DC, internal
Max. Power Consumption 240W
Max. PoE Wattage per Port 30W
LEDs W/B Learn More
Buttons (1) Factory reset
UA-Lock-Electric (400mA) 24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA) 24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA) 24 AWG length: 12 m (29 ft) 22 AWG length: 20 m (98 ft) 20 AWG length: 30 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A) 24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 Statement Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Grade Grade assignment: I
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level EAH-8, Ver 01