SG3428XPP-M2
$1,099.99
Skip to product information
Out of stock





SG3428XPP-M2
$1,099.99
24 Port 2.5 Gig PoE+ Switch
Omada 24-Port 2.5GBASE-T and 4-Port 10GE SFP+ L2+ Managed Switch with 16-Port PoE+ & 8-Port PoE++. FEATURE: Integration with Omada SDN Controller, Static Routing, OAM, DDM, 802.1Q VLAN, QinQ, STP/RSTP/MSTP, IGMP Snooping, 802.1p/DSCP QoS, ACL, 802.1x, Radius/Tacacs+ Authentication, LACP, CLI, SNMP, Dual Image/Configuration, IPv6
Get notified when
SG3428XPP-M2 is back in stock.
No spam. One single email when the product is available.
You're all set! You'll receive an email as soon as the product is back in stock.
24 Port 2.5 Gig PoE+ Switch
24× 2.5 Gbps RJ45 Ports
(8× PoE++, 16× PoE+)
4× 10 Gbps
SFP+ Slots
Centralized
Management†
Omada
App†
500 W Total PoE Budget (Max
60 W for Each PoE++ Port)*
Zero-Touch
Provisioning†
Ethernet Ring
Protection Switching
Static
Routing
Access
Points
PTZ HD IP Cameras
with Heaters
Smart Building
Lighting
Audio
System
2.5G
NAS/Server
Lightning-fast aggregation switching
Remotely manage your access points, switches, and gateways across multiple sites all from a single interface.
Highlights
- 10G Router
- Full 10G Fiber Switch
| Fabricant | TP-Link |
| Modèle | SG3428XPP-M2 |
| UPC | 840030709739 |
| Catégorie | Networking — Switches 18 to 24 Ports |
| Poids | 13.6 lbs |
| Dimensions (boîte) | 21.2" × 17.4" × 4" (L×P×H) |
Specifications
General
| Interface | • 24× 2.5 Gbps RJ45 Ports (8× PoE++, 16× PoE+)• 4× 10G SFP+ Slots• 1× RJ45 Console Port• 1× Micro-USB Console Port |
| Fan Quantity | 3 |
| Physical Security Lock | √ |
| Power Supply | 100-240 V AC~50/60 Hz |
| PoE Ports (RJ45) | • Standard: 802.3bt/at/af compliant• PoE++ Ports (802.3bt/at/af PoE): 8 Ports, up to 60 W per port• PoE+ Ports (802.3at/af PoE): 16 Ports, up to 30 W per port• Power Budget: 500 W |
| Dimensions ( W x D x H ) | 17.3×13.0×1.7 in (440×330×44 mm) |
| Mounting | Rack Mountable |
| Max. Power Consumption | 629.1 W (110V/60Hz) |
| Max. Heat Dissipation | 2153.45 BTU/h (110 V/60 Hz) |
| Packet Buffer Memory | 16 Mbit |
| Jumbo Frame | 9 KB |
| Switching Capacity | 200 Gbps |
| Packet Forwarding Rate | 148.80 Mpps |
| MAC Address Table | 32 K |
| Quality of Service | • 8 priority queues• 802.1p CoS/DSCP priority• Queue scheduling: SP (Strict Priority), WRR (Weighted Round Robin), SP+WRR• Bandwidth Control: Port/Flow-based Rating Limiting• Smoother Performance• Action for Flows: QoS remark (802.1P Remark, DSCP Remark) |
| L2 and L2+ Features | • 32 IP Interfaces: Support IPv4/IPv6 Interface• Static Routing: 48 IPv4/IPv6 Static Routes• Static ARP: 128 static entries• 512 ARP Entries• Proxy ARP• Gratuitous ARP• DHCP Server• DHCP Relay: DHCP Interface Relay, DHCP VLAN Relay• DHCP L2 Relay• Link Aggregation• Spanning Tree Protocol• Loopback Detection• 802.3x Flow Control• Mirroring |
| L2 Multicast | • Supports 511 (IPv4, IPv6) IGMP groups• IGMP Snooping• IGMP Authentication• Multicast VLAN Registration (MVR)• MLD Snooping• Multicast Filtering: 256 profiles and 16 entries per profile |
| Advanced Features | • Automatic Device Discovery†• Batch Configuration†• Batch Firmware Upgrading†• Intelligent Network Monitoring†• Abnormal Event Warnings†• Unified Configuration†• Reboot Schedule†ISP Features***:• L2PT (Layer 2 Protocol Tunneling) • Device Link Detect Protocol (DLDP)• PPPoE ID Insertion• ERPS• 802.3ah Ethernet Link OAM• DDM |
| VLAN | • VLAN Group: Max 4K VLAN Groups• 802.1q Tagged VLAN• MAC VLAN: 256 Entries• Protocol VLAN: Protocol Template 16, Protocol VLAN 16• GVRP• VLAN VPN: VLAN Mapping, VLAN Replace• Voice VLAN |
| Access Control List | • Time-based ACL• MAC ACL: Source MAC, Destination MAC, VLAN ID, User Priority, Ether Type• IP ACL: Source IP, Destination IP, Fragment, IP Protocol, TCP Flag, TCP/UDP Port, DSCP/IP TOS• Combined ACL• Packet Content ACL• IPv6 ACL• Policy: Mirroring, Redirect, Rate Limit, QoS Remark• ACL applies to Port/VLAN |
| IPv6 | • IPv6 Dual IPv4/IPv6• Multicast Listener Discovery (MLD) Snooping• IPv6 ACL• IPv6 Interface• Static IPv6 Routing• IPv6 neighbor discovery (ND)• Path maximum transmission unit (MTU) discovery• Internet Control Message Protocol (ICMP) version 6• TCPv6/UDPv6• IPv6 applications: DHCPv6 Client, Ping6, Tracert6, Telnet (v6), IPv6 SNMP, IPv6 SSH, IPv6 SSL, Http/Https, IPv6 TFTP |
| MIBs | • MIB II (RFC1213)• Interface MIB (RFC2233)• Ethernet Interface MIB (RFC1643)• Bridge MIB (RFC1493)• P/Q-Bridge MIB (RFC2674)• RMON MIB (RFC2819)• RMON2 MIB (RFC2021)• Radius Accounting Client MIB (RFC2620)• Radius Authentication Client MIB (RFC2618)• Remote Ping, Traceroute MIB (RFC2925)• Support TP-Link private MIB |
| Omada App | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
| Centralized Management | • Omada Cloud-Based Controller• Omada Hardware Controller• Omada Software Controller |
| Cloud Access | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
| Zero-Touch Provisioning | Yes. Requiring the use of Omada Cloud-Based Controller. |
| Management Features | • Web-based GUI• Command Line Interface (CLI) through the console port, telnet• SNMP v1/v2c/v3: Trap/Inform, RMON (1,2,3,9 groups)• SDM Template• DHCP/BOOTP Client• 802.1ab LLDP/LLDP-MED• DHCP AutoInstall• Dual Image, Dual Configuration• CPU Monitoring• Cable Diagnostics• EEE• Password Recovery• SNTP• System Log |
| Certification | CE, FCC, RoHS |
| Package Content | • SG3428XPP-M2 Switch• Power Cord• Quick Installation Guide• Rackmount Kit• Rubber Feet |
| System Requirements | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux. |
| Environment | • Operating Temperature: 0–40 ℃ (32–104 ℉);• Storage Temperature: -40–70 ℃ (-40–158 ℉)• Operating Humidity: 10–90% RH non-condensing• Storage Humidity: 5–90% RH non-condensing |





General
| Interface | • 24× 2.5 Gbps RJ45 Ports (8× PoE++, 16× PoE+)• 4× 10G SFP+ Slots• 1× RJ45 Console Port• 1× Micro-USB Console Port |
| Fan Quantity | 3 |
| Physical Security Lock | √ |
| Power Supply | 100-240 V AC~50/60 Hz |
| PoE Ports (RJ45) | • Standard: 802.3bt/at/af compliant• PoE++ Ports (802.3bt/at/af PoE): 8 Ports, up to 60 W per port• PoE+ Ports (802.3at/af PoE): 16 Ports, up to 30 W per port• Power Budget: 500 W |
| Dimensions ( W x D x H ) | 17.3×13.0×1.7 in (440×330×44 mm) |
| Mounting | Rack Mountable |
| Max. Power Consumption | 629.1 W (110V/60Hz) |
| Max. Heat Dissipation | 2153.45 BTU/h (110 V/60 Hz) |
| Packet Buffer Memory | 16 Mbit |
| Jumbo Frame | 9 KB |
| Switching Capacity | 200 Gbps |
| Packet Forwarding Rate | 148.80 Mpps |
| MAC Address Table | 32 K |
| Quality of Service | • 8 priority queues• 802.1p CoS/DSCP priority• Queue scheduling: SP (Strict Priority), WRR (Weighted Round Robin), SP+WRR• Bandwidth Control: Port/Flow-based Rating Limiting• Smoother Performance• Action for Flows: QoS remark (802.1P Remark, DSCP Remark) |
| L2 and L2+ Features | • 32 IP Interfaces: Support IPv4/IPv6 Interface• Static Routing: 48 IPv4/IPv6 Static Routes• Static ARP: 128 static entries• 512 ARP Entries• Proxy ARP• Gratuitous ARP• DHCP Server• DHCP Relay: DHCP Interface Relay, DHCP VLAN Relay• DHCP L2 Relay• Link Aggregation• Spanning Tree Protocol• Loopback Detection• 802.3x Flow Control• Mirroring |
| L2 Multicast | • Supports 511 (IPv4, IPv6) IGMP groups• IGMP Snooping• IGMP Authentication• Multicast VLAN Registration (MVR)• MLD Snooping• Multicast Filtering: 256 profiles and 16 entries per profile |
| Advanced Features | • Automatic Device Discovery†• Batch Configuration†• Batch Firmware Upgrading†• Intelligent Network Monitoring†• Abnormal Event Warnings†• Unified Configuration†• Reboot Schedule†ISP Features***:• L2PT (Layer 2 Protocol Tunneling) • Device Link Detect Protocol (DLDP)• PPPoE ID Insertion• ERPS• 802.3ah Ethernet Link OAM• DDM |
| VLAN | • VLAN Group: Max 4K VLAN Groups• 802.1q Tagged VLAN• MAC VLAN: 256 Entries• Protocol VLAN: Protocol Template 16, Protocol VLAN 16• GVRP• VLAN VPN: VLAN Mapping, VLAN Replace• Voice VLAN |
| Access Control List | • Time-based ACL• MAC ACL: Source MAC, Destination MAC, VLAN ID, User Priority, Ether Type• IP ACL: Source IP, Destination IP, Fragment, IP Protocol, TCP Flag, TCP/UDP Port, DSCP/IP TOS• Combined ACL• Packet Content ACL• IPv6 ACL• Policy: Mirroring, Redirect, Rate Limit, QoS Remark• ACL applies to Port/VLAN |
| IPv6 | • IPv6 Dual IPv4/IPv6• Multicast Listener Discovery (MLD) Snooping• IPv6 ACL• IPv6 Interface• Static IPv6 Routing• IPv6 neighbor discovery (ND)• Path maximum transmission unit (MTU) discovery• Internet Control Message Protocol (ICMP) version 6• TCPv6/UDPv6• IPv6 applications: DHCPv6 Client, Ping6, Tracert6, Telnet (v6), IPv6 SNMP, IPv6 SSH, IPv6 SSL, Http/Https, IPv6 TFTP |
| MIBs | • MIB II (RFC1213)• Interface MIB (RFC2233)• Ethernet Interface MIB (RFC1643)• Bridge MIB (RFC1493)• P/Q-Bridge MIB (RFC2674)• RMON MIB (RFC2819)• RMON2 MIB (RFC2021)• Radius Accounting Client MIB (RFC2620)• Radius Authentication Client MIB (RFC2618)• Remote Ping, Traceroute MIB (RFC2925)• Support TP-Link private MIB |
| Omada App | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
| Centralized Management | • Omada Cloud-Based Controller• Omada Hardware Controller• Omada Software Controller |
| Cloud Access | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
| Zero-Touch Provisioning | Yes. Requiring the use of Omada Cloud-Based Controller. |
| Management Features | • Web-based GUI• Command Line Interface (CLI) through the console port, telnet• SNMP v1/v2c/v3: Trap/Inform, RMON (1,2,3,9 groups)• SDM Template• DHCP/BOOTP Client• 802.1ab LLDP/LLDP-MED• DHCP AutoInstall• Dual Image, Dual Configuration• CPU Monitoring• Cable Diagnostics• EEE• Password Recovery• SNTP• System Log |
| Certification | CE, FCC, RoHS |
| Package Content | • SG3428XPP-M2 Switch• Power Cord• Quick Installation Guide• Rackmount Kit• Rubber Feet |
| System Requirements | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux. |
| Environment | • Operating Temperature: 0–40 ℃ (32–104 ℉);• Storage Temperature: -40–70 ℃ (-40–158 ℉)• Operating Humidity: 10–90% RH non-condensing• Storage Humidity: 5–90% RH non-condensing |
Contents not available.
Pour les questions fréquentes, consultez le centre d'aide Ubiquiti :
❓ Centre d'aide Ubiquiti