Door Hub

A single-door mechanism that provides complete entry and exit control via connected Access Readers. (2) Lock terminals (12V and Dry) (2) AUX terminals for an external siren and automatic door opener (4) Additional inputs (sensors and buttons) Connect and power using PoE++ Connect to two UniFi Access readers and two UniFi Protect camera or UniFi Protect Chime.

Volume Discounts
1 $310.99/ea
2-4 $309.70/ea
5-9 $308.41/ea
10-19 $305.84/ea
20+ $303.26/ea

Door Hub

Fabricant Ubiquiti
Modèle UA-Hub-Door
UPC 810084690598
Catégorie Surveillance & Security — Accessories
Poids 1.5 lbs
Dimensions (boîte) 4.9" × 5.6" × 1.6" (L×P×H)
ProductProductProductProduct
Overview
Dimensions 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3")
Supported Doors 1
Maximum User Count 6,000
Input Terminals (2) Door exit request (1) Door position (1) Emergency
Power Method PoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
NDAA Compliant
UL 294 Level Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Weight 363 g (12.8 oz)
Enclosure Material Polycarbonate
Mount Material Polycarbonate
Mounting DIN-rail (Included)
Digital Input Request to exit, request to enter, remote release, door position sensor
Dry Output Relay Lock: 30V DC, 1A Aux: 30V DC, 1A
Powered Output Relay Lock: 12V DC, 1A Aux: 12V DC, 0.33A 12V DC, 0.33A
Indoor and Outdoor Use Indoor only
Ambient Operating Temperature 0 to 40° C (32 to 104° F)
Ambient Operating Humidity 5 to 95% noncondensing
Networking Interface (5) 10/100/1000 Base-T
PoE Interface (1) PoE++ input, 50V DC, 1A (4) PoE+ outputs, 50V DC, 30W per port (Max 45W aggregated)
Max. Power Consumption 30W (Without PoE output) 50W (With PoE output)
LEDs W/B Learn More
Buttons (1) Factory reset
UA-Lock-Electric (400mA) 24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA) 24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA) 24 AWG length: 12 m (29 ft) 22 AWG length: 20 m (98 ft) 20 AWG length: 30 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A) 24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 Statement Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Grade Grade assignment: 1
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level UA-Hub-Door002, V01
Management Application Access
Software Information The software version can be checked at https://unifi.ui.com
Specs
Dimensions 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3")
Supported Doors 1
Maximum User Count 6,000
Input Terminals (2) Door exit request (1) Door position (1) Emergency
Power Method PoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
NDAA Compliant
UL 294 Level Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Weight 363 g (12.8 oz)
Enclosure Material Polycarbonate
Mount Material Polycarbonate
Mounting DIN-rail (Included)
Digital Input Request to exit, request to enter, remote release, door position sensor
Dry Output Relay Lock: 30V DC, 1A Aux: 30V DC, 1A
Powered Output Relay Lock: 12V DC, 1A Aux: 12V DC, 0.33A 12V DC, 0.33A
Indoor and Outdoor Use Indoor only
Ambient Operating Temperature 0 to 40° C (32 to 104° F)
Ambient Operating Humidity 5 to 95% noncondensing
Networking Interface (5) 10/100/1000 Base-T
PoE Interface (1) PoE++ input, 50V DC, 1A (4) PoE+ outputs, 50V DC, 30W per port (Max 45W aggregated)
Max. Power Consumption 30W (Without PoE output) 50W (With PoE output)
LEDs W/B Learn More
Buttons (1) Factory reset
UA-Lock-Electric (400mA) 24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA) 24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA) 24 AWG length: 12 m (29 ft) 22 AWG length: 20 m (98 ft) 20 AWG length: 30 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A) 24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 Statement Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Grade Grade assignment: 1
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level UA-Hub-Door002, V01